STATCON POWTECH ‘Off Grid’ series of Single Phase PCU are designed to meet the growing electricity demand of developing countries. The state of art design and intelligent control optimizes the yield of all small and medium level PV plant.

STATCON POWTECH ‘Off Grid PCU’ consist of ‘MPPT’ based charge controller and bi-directional inverter with a transformer on AC side. It provides uninterrupted power to the load using solar, battery and grid input in same order of priority. In-house developed latest DSP based pure sine wave technology ensures excellent performance, protection from any kind of malfunction and the high conversion efficiency is achieved. The high conversion efficiency helps in longer battery backup. Ease of operation and plug & play type of design make it an ideal product for all uses. These ‘Off Grid PCU’ are capable of being configured for priority of solar, battery or grid as described below:

SALIENT FEATURES

When solar energy is sufficient then the output of MPPT charges the batteries along with feeding inverter to produce AC to meet load demand. If solar is not sufficient to charge the battery then both MPPT charger and grid charger charges the battery, in this condition max. power yields from solar to charge the battery.

BATTERY PRIORITY

When MPPT is not sufficient to meet load demand then the combination of MPPT output and batteries are used to feed an inverter to produce AC to meet load demand.

MAINS AT PRIORITY

If the battery has low voltage condition then the load is shifted to grid and batteries are charged through MPPT. If MPPT is not available to charge batteries then grid charger becomes active to charge batteries and load is fed from a grid. Once the batteries are fully charged the load is automatically shifted on solar and batteries.

Statcon Powtech PCU with higher rated MPPT is available on demand. Statcon Powtech also offers ‘Off Grid PCU’ for welding sets. Statcon Powtech Pump Combo Series is capable of working with DC Pump, utilizing same solar panels installed for DC pumps.

SALIENT FEATURES
  • Excellent yield from solar through MPPT based charger controller.
  • Rapid charging in minimum time through mains charger.
  • Suited for all battery types.
  • High efficiency at full/half loads.
  • Galvanic isolation on AC side.
  • 3 stage battery charging, current limiting, temp.compensation.
  • Excellent performance up to 50 degrees of temperature.
  • Digital display with fault & energy logging.
  • Remote monitoring over internet & RS 485.
  • Available in different capacities & battery voltages.
  • Various modes of operation to suit all types of users.
APPLICATIONS
  • Rural Electrification
  • Remote Sites
  • Farm Houses
  • Government Rural Health Schemes
  • Remote Telecom/Oil/Gas pipelines
  • Defense

SOLAR OFF GRID PCU SPECIFICATION

  Rating 1KW 2KW 3KW 5KW 6KW 7.5KW 10KW 15KW
1 DC Voltage 24/48V 48V 48V 96V 96V 96V 120V 180V
2 Input range

22-30V for 24V,

44-60V for 48V

44-60V 44-60V 85-115V 85-115V 85-115V 108-144V 162-216V
3 Nominal O/P 230V, ±2%, 50Hz 230V, ±2%, 50Hz 230V, ±2%, 50Hz 230V, ±2%, 50Hz 230V, ±2%, 50Hz 230V, ±2%, 50Hz 230V, ±2%, 50Hz 230V, ±2%, 50Hz
4 DC-AC efficiency >85% >87% >87% >87% >87% >87% >88% >90%
5 Standby power <50W <50W <50W <200W <200W <200W <200W <300W
6 THD <5% <5% <5% <5% <5% <5% <5% <5%
7 Load PF Lag 0.8 to unity Lag 0.8 to unity Lag 0.8 to unity Lag 0.8 to unity Lag 0.8 to unity Lag 0.8 to unity Lag 0.8 to unity Lag 0.8 to unity
8 MPPT Range 60-140V 60-140V 60-140V 135-200V 135-200V 135-200V 160-275V 250-400V
9 Max. PV Voltage 150V 150V 150V 230V 230V 230V 320V 450V
9 PV capacity 1Kwp 2Kwp 3Kwp 5Kwp 6Kwp 7.5Kwp 10Kwp 15Kwp
10 MPPT efficiency >92% >92% >92% >93% >93% >93% >94% >94%
11 Over load 1. 125%- 60 sec.
2. 150%- 30 sec.,
3. >150% Immediate trip
1. 125%- 60 sec.
2. 150%- 30 sec.,
3. >150% Immediate trip
1. 125%- 60 sec.
2. 150%- 30 sec.,
3. >150% Immediate trip
1. 125%- 60 sec.
2. 150%- 30 sec.,
3. >150% Immediate trip
1. 125%- 60 sec.
2. 150%- 30 sec.,
3. >150% Immediate trip
1. 125%- 60 sec.
2. 150%- 30 sec.,
3. >150% Immediate trip
1. 125%- 60 sec.
2. 150%- 30 sec.,
3. >150% Immediate trip
1. 125%- 60 sec.
2. 150%- 30 sec.,
3. >150% Immediate trip
12 Indication 1. Power ON
2. Inverter ON,
3. MPPT charging ON,
4. Mains Charging/Grid ON,
5. PV Present/PV ON
6. Fault
1. Power ON
2. Inverter ON,
3. MPPT charging ON,
4. Mains Charging/Grid ON,
5. PV Present/PV ON
6. Fault
1. Power ON
2. Inverter ON,
3. MPPT charging ON,
4. Mains Charging/Grid ON,
5. PV Present/PV ON
6. Fault
1. Power ON
2. Inverter ON,
3. MPPT charging ON,
4. Mains Charging/Grid ON,
5. PV Present/PV ON
6. Fault
1. Power ON
2. Inverter ON,
3. MPPT charging ON,
4. Mains Charging/Grid ON,
5. PV Present/PV ON
6. Fault
1. Power ON
2. Inverter ON,
3. MPPT charging ON,
4. Mains Charging/Grid ON,
5. PV Present/PV ON
6. Fault
1. Power ON
2. Inverter ON,
3. MPPT charging ON,
4. Mains Charging/Grid ON,
5. PV Present/PV ON
6. Fault
1. Power ON
2. Inverter ON,
3. MPPT charging ON,
4. Mains Charging/Grid ON,
5. PV Present/PV ON
6. Fault
13 Protections 1.Battery & PV reverse Polarity Protection,
2. Output Short Circuit,
3. Battery Over Voltage,
4. Battery Under Voltage,
5. Mains Under/Over Voltage.
6. System Over Temperature,
7. Solar Over Load,
8. Battery Current Limit
1.Battery & PV reverse Polarity Protection,
2. Output Short Circuit,
3. Battery Over Voltage,
4. Battery Under Voltage,
5. Mains Under/Over Voltage.
6. System Over Temperature,
7. Solar Over Load,
8. Battery Current Limit
1.Battery & PV reverse Polarity Protection,
2. Output Short Circuit,
3. Battery Over Voltage,
4. Battery Under Voltage,
5. Mains Under/Over Voltage.
6. System Over Temperature,
7. Solar Over Load,
8. Battery Current Limit
1.Battery & PV reverse Polarity Protection,
2. Output Short Circuit,
3. Battery Over Voltage,
4. Battery Under Voltage,
5. Mains Under/Over Voltage.
6. System Over Temperature,
7. Solar Over Load,
8. Battery Current Limit
1.Battery & PV reverse Polarity Protection,
2. Output Short Circuit,
3. Battery Over Voltage,
4. Battery Under Voltage,
5. Mains Under/Over Voltage.
6. System Over Temperature,
7. Solar Over Load,
8. Battery Current Limit
1.Battery & PV reverse Polarity Protection,
2. Output Short Circuit,
3. Battery Over Voltage,
4. Battery Under Voltage,
5. Mains Under/Over Voltage.
6. System Over Temperature,
7. Solar Over Load,
8. Battery Current Limit
1.Battery & PV reverse Polarity Protection,
2. Output Short Circuit,
3. Battery Over Voltage,
4. Battery Under Voltage,
5. Mains Under/Over Voltage.
6. System Over Temperature,
7. Solar Over Load,
8. Battery Current Limit
1.Battery & PV reverse Polarity Protection,
2. Output Short Circuit,
3. Battery Over Voltage,
4. Battery Under Voltage,
5. Mains Under/Over Voltage.
6. System Over Temperature,
7. Solar Over Load,
8. Battery Current Limit
14 Switch gears 1. Battery- MCB
2. PV-MCB,
3. Mains-MCB,
4. Load-MCB
1. Battery- MCB
2. PV-MCB,
3. Mains-MCB,
4. Load-MCB
1. Battery- MCB
2. PV-MCB,
3. Mains-MCB,
4. Load-MCB
1. Battery- MCB
2. PV-MCB,
3. Mains-MCB,
4. Load-MCB
1. Battery- MCB
2. PV-MCB,
3. Mains-MCB,
4. Load-MCB
1. Battery- MCB
2. PV-MCB,
3. Mains-MCB,
4. Load-MCB
1. Battery- MCB
2. PV-MCB,
3. Mains-MCB,
4. Load-MCB
1. Battery- MCB
2. PV-MCB,
3. Mains-MCB,
4. Load-MCB
15 Surge Protection MOV at all input/output feeder MOV at all input/output feeder MOV at all input/output feeder MOV at all input/output feeder MOV at all input/output feeder MOV at all input/output feeder MOV at all input/output feeder MOV at all input/output feeder
16 Display 1. Battery volt. Battery Amp
2. PV Volt. PV Amp,
3. Inverter Volt, Inverter Amp.,
4. Inverter KVA,
5. Inverter Freq.
6. PV KW,
7. PV KWH ,
8. Mains Volt. Mains Amp. ,
9. Data logging of solar energy for 30days
1. Battery volt. Battery Amp
2. PV Volt. PV Amp,
3. Inverter Volt, Inverter Amp.,
4. Inverter KVA,
5. Inverter Freq.
6. PV KW,
7. PV KWH ,
8. Mains Volt. Mains Amp. ,
9. Data logging of solar energy for 30days
1. Battery volt. Battery Amp
2. PV Volt. PV Amp,
3. Inverter Volt, Inverter Amp.,
4. Inverter KVA,
5. Inverter Freq.
6. PV KW,
7. PV KWH ,
8. Mains Volt. Mains Amp. ,
9. Data logging of solar energy for 30days
1. Battery volt. Battery Amp
2. PV Volt. PV Amp,
3. Inverter Volt, Inverter Amp.,
4. Inverter KVA,
5. Inverter Freq.
6. PV KW,
7. PV KWH ,
8. Mains Volt. Mains Amp. ,
9. Data logging of solar energy for 30days
1. Battery volt. Battery Amp
2. PV Volt. PV Amp,
3. Inverter Volt, Inverter Amp.,
4. Inverter KVA,
5. Inverter Freq.
6. PV KW,
7. PV KWH ,
8. Mains Volt. Mains Amp. ,
9. Data logging of solar energy for 30days
1. Battery volt. Battery Amp
2. PV Volt. PV Amp,
3. Inverter Volt, Inverter Amp.,
4. Inverter KVA,
5. Inverter Freq.
6. PV KW,
7. PV KWH ,
8. Mains Volt. Mains Amp. ,
9. Data logging of solar energy for 30days
1. Battery volt. Battery Amp
2. PV Volt. PV Amp,
3. Inverter Volt, Inverter Amp.,
4. Inverter KVA,
5. Inverter Freq.
6. PV KW,
7. PV KWH ,
8. Mains Volt. Mains Amp. ,
9. Data logging of solar energy for 30days
1. Battery volt. Battery Amp
2. PV Volt. PV Amp,
3. Inverter Volt, Inverter Amp.,
4. Inverter KVA,
5. Inverter Freq.
6. PV KW,
7. PV KWH ,
8. Mains Volt. Mains Amp. ,
9. Data logging of solar energy for 30days
17 Operating temp. range -10°-55°C -10°-55°C -10°-55°C -10°-55°C -10°-55°C -10°-55°C -10°-55°C -10°-55°C
18 Dimension 530X280X325MM 530X280X325MM 530X280X325MM 530X280X325MM 530X280X325MM 530X280X325MM 530X280X325MM 530X280X325MM
19 Storage Temp. -10°-60°C -10°-60°C -10°-60°C -10°-60°C -10°-60°C -10°-60°C -10°-60°C -10°-60°C

 

 
Recommended Panel Array

 

20

No. of Panels in series(250W/ 37VOC)

4 4 4 6 6 6 8 12  
21 No. of Rows 1 2 3 3 4 5 5 5

Note:-

Communication: RS 232 standard

GPRS: Optional

* System with different voltage are available on request. ** Panels in all rows should be equal.

 

A Complete Solar Solution Company

If you require services for construction or renovation, simply
call our 24/7 support.

+91-0120-4313876  or Contact Us